Key technical parameters confirmed by testing:

Test Method ASTM D 2671:

  • Tensile strength: ≥ 14 MPa

  • Elongation at break: ≥ 400%

  • Elongation at break after heat aging (+150°C, 168h): ≥ 300%

  • Influence on copper: Non-corrosive

  • Cold bend (-55°C, 4h): No cracking

Test Method UL 224:

  • Longitudinal change after recovery: 0% to -10%

Test Method IEC 243:

  • Dielectric strength: ≥ 20 kV/mm

Test Method IEC 93:

  • Volume resistivity: ≥ 1014 Ω⋅ cm

Test Method ASTM D 1693:

  • Stress cracking resistance (+50°C): No cracking

Test Method ISO 62:

  • Water absorption: < 0.1%

Test Method ASTM E 28:

  • Softening point: 80°C

Test Method ASTM D 1000:

  • Peel strength: 50 N / 25 mm

Test Method ISO 846:

  • Fungus resistance: Resistant